EcoMBR1 - Configure the relay
Switch by grid power, electricity price or switch
The relay has two controls, which you switch on individually in the web interface, and a switch input:
| Setting | Meaning |
|---|---|
| Grid Relay Control | switch control by grid power (the meter's Grid Active Power value) on or off |
| Grid Relay ON / Grid Relay OFF | on and off switching point in watts (−20 000 … 20 000 W) |
| Tibber Relay Control | switch control by the Tibber electricity price (the Tibber Price value) on or off |
| Tibber Price ON / Tibber Price OFF | on and off switching point as a price per kWh, in the unit chosen under Tibber Price Unit |
| Relay 1 | the relay itself. Can be switched by hand as long as no control is switched on |
All settings are kept after a restart.
When a control is available
- Grid Relay Control needs an electricity meter. If none is connected or it does not answer (Meter Status reads
no response), the control cannot be switched on. If the meter fails during operation, the control rests until it answers again. - Tibber Relay Control needs a Tibber token (Electricity price from Tibber). Without a token the control cannot be switched on. If the token is deleted, the control switches itself off. As long as the sensor receives no price, it does not switch the relay on.
How the switching points work
- If ON is below OFF, the relay switches on below ON and off above OFF. This is the usual case: switch on at surplus or when electricity is cheap.
- If ON is above OFF, it is the other way round: on above ON, off below OFF.
- Between the two switching points the relay stays as it is. The gap prevents constant switching back and forth.
| Example | Setting | Effect |
|---|---|---|
| Use solar surplus | Grid Relay ON -500, Grid Relay OFF -100 |
on at more than 500 W feed-in, off at less than 100 W (feed-in is negative) |
| Use cheap electricity | Tibber Price ON 0.20, Tibber Price OFF 0.25 (unit EUR/kWh) |
on below 0.20 EUR/kWh, off above 0.25 EUR/kWh |
If both controls are switched on, the relay is on as soon as one of them switches it on.
The switching points for the price apply in the chosen Tibber Price Unit. If you change the unit (for example from EUR/kWh to ct/kWh), adjust both values.
"Permanently on" switch
A switch can be connected to the switch input (IO19, see Connecting):
- Switch ON (closed): the relay is permanently on, no matter which control is switched on.
- Switch OFF (open): the relay works according to the controls that are switched on.
Indicators
| Indicator | Meaning |
|---|---|
| Relay Status | what currently drives the relay: override (the switch is ON), grid, tibber or grid+tibber (this control switches on), off (controls switched on, none switches on), manual (no control switched on) |
| Relay Override | position of the switch at the switch input |
| Meter Status | ok or no response (no meter connected or it does not answer) |
After an update from older firmware: there the control was called Relay Control with Relay 1 On Limit / Relay 1 Off Limit. After the update, Grid Relay Control is switched off and both switching points are 0. Enter the values again and switch the control back on.